Det-Tronics X3300 Protect-IR Multispectrum IR Flame Detector with Pulse Output User Manual

Page 11

Advertising
background image

9

95-8517

J1-7
J1-15

J1-5
J1-13

J1-6
J1-14

J1-8
J1-16

J1-9
J1-17

J1-10
J1-18

J1-11
J1-19

J2

J1

RED

BLACK

WHITE

GREEN

X3300

DETECTOR 1

RED
BLACK
WHITE
GREEN

RED

BLACK

WHITE

GREEN

X3300

DETECTOR 2

RED
BLACK
WHITE
GREEN

RED

BLACK

WHITE

GREEN

X3300

DETECTOR 3

RED
BLACK
WHITE
GREEN

RED

BLACK

WHITE

GREEN

X3300

DETECTOR 4

RED
BLACK
WHITE
GREEN

RED

BLACK

WHITE

GREEN

X3300

DETECTOR 5

RED
BLACK
WHITE
GREEN

RED

BLACK

WHITE

GREEN

X3300

DETECTOR 6

RED
BLACK
WHITE
GREEN

RED

BLACK

WHITE

GREEN

X3300

DETECTOR 7

RED
BLACK
WHITE
GREEN

RED

BLACK

WHITE

GREEN

X3300

DETECTOR 8

RED

BLACK
WHITE
GREEN

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

+24 VDC

CIRCUIT GROUND

+24 VDC

B1 - INPUT SIGNAL

B2 - INPUT SIGNAL

B3 - INPUT SIGNAL

B4 - INPUT SIGNAL

B5 - INPUT SIGNAL

B6 - INPUT SIGNAL

B7 - INPUT SIGNAL

B8 - INPUT SIGNAL

D1 oi DRIVER

D2 oi DRIVER

D3 oi DRIVER

D4 oi DRIVER

D5 oi DRIVER

D6 oi DRIVER

D7 oi DRIVER

D8 oi DRIVER

DATA BUS OUT

DATA BUS OUT

DATA BUS OUT

DATA BUS OUT

DATA BUS OUT

DATA BUS OUT

DATA BUS OUT

DATA BUS OUT

NOT USED

NOT USED

DATA STROBE IN

NOT USED

NOT USED

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

58

59

60

61

62

63

64

ZONE OUTPUT 1

ZONE OUTPUT 2

ZONE OUTPUT 3

ZONE OUTPUT 4

ZONE OUTPUT 5

ZONE OUTPUT 6

ZONE OUTPUT 7

ZONE OUTPUT 8

FIRE LOGIC “A”

FIRE LOGIC “B”

ALARM OUTPUT

EXTERNAL RESET/INHIBIT

OUTPUTS INHIBITED

FAULT OUTPUT

EXTERNAL ACCEPT

STATUS & DET. OUTPUT S1

STATUS & DET. OUTPUT S2

STATUS & DET. OUTPUT S3

STATUS & DET. OUTPUT S4

STATUS & DET. OUTPUT S5

STATUS & DET. OUTPUT S6

STATUS & DET. OUTPUT S7

STATUS & DET. OUTPUT S8

DATA BUS 0

DATA BUS 1

DATA BUS 2

DATA BUS 3

DATA BUS 4

DATA BUS 5

DATA BUS 6

DATA BUS 7

EARTH GROUND

R7494 CONTROLLER

A2012

NOTE: IF THE POWER SUPPLY MINUS CANNOT BE CONNECTED

TO CHASSIS (EARTH) GROUND, CONNECT A 0.47

µ

F 250 VDC

NON-POLARIZED CAPACITOR BETWEEN J1-2 AND J2-64.

NOTE: 2.5 AMPERES @ 24 VDC REQUIRED PER EIGHT DETECTORS.

62

63

64

TO J1-2

0.47

µ

F / 250 VDC

NON-POLARIZED

GROUND FAULT PROTECTED SYSTEMS

24

VDC

+

TERMINAL NO.

FUNCTION

1

DC+ ("A" LEAD)

2

SIGNAL ("B" LEAD)

3

DC– ("C" LEAD)

4

Oi ("D" LEAD)

TERMINAL IDENTIFICATION FOR X3300

WITH INTEGRAL JUNCTION BOX.

Figure 8—A Typical System, X3300 Detectors Wired to R7494 Controller