Ordering information, Options – Det-Tronics C7050 A, C, G, P UV Flame Detector User Manual

Page 26

Advertising
background image

Det-Tronics Benelux
Costerweg 5
NL-6702 AA Wageningen
THE NETHERLANDS
Telephone 31 (0)317 497625
Facsimile 31 (0)317 427308

117333 Moscow
Gubkina St, d.3
Gipronii Ran
Kidde Graviner
RUSSIA
Telephone 7 (095) 135 5389
Facsimile 7 (502) 222 1276

Det-Tronics Scandinavia AB
Box 81
S-260 83 Vejbystrand
SWEDEN
Telephone 431-53002/53240
Facsimile 431-52236

Detector Electronics Corporation
C/O Kidde International Protection Systems
143 Cecil Street
#15-01 G. B. Building
SINGAPORE 0106
Telephone (65) 220-1355
Facsimile (65) 226-6305

Detector Electronics Middle East
C/O Kidde International
P O Box 30791
BUAMEEM II Building
Umm Hureir Road
Dubai, U.A.E.
Telephone 971 4 372498
Facsimile 971 4 375088

Det-Tronics South America.
Calle 72 con Avenida 3H
Centro Comercial “Las Tinajitas”
Local No. 18
2do. Nivel
Maracaibo, VENEZUELA
Telephone 58-61-926885
Facsimile 58-61-926525

Detector do Brasil
Avenida Geremario Dantas 493
Rio de Janeiro 22740-011
BRAZIL
Telephone (55) 21 392 9633
Facsimile (55) 21 392 5568

ORDERING INFORMATION

When ordering specify:
— R7404 Controller
— C7050 Detector
— Detector housing material

Aluminum
Nickel-plated brass
316 stainless steel

— Cover locking assembly (if required to comply with

local regulations)

Special Purpose C7050 Detectors:

Nuclear Surveillance Detector

for applications

involving x-rays or gamma radiation.

Internal Reflection

oi

can extend detector mainte-

nance intervals in applications involving oily contami-
nants.

Special Purpose R7404 Controllers:

STAR (Selectable Transient Arc Rejection) Logic
Controller

is recommended for applications where

transient electric arcs, such as those produced in
electrostatic power coating or paint spraying booths,
can cause false actuation of a standard UV system.

High Speed Suppression Controller

is designed for

use with the R1425 Detonator Module for protecting
installations where extremely fast system response
times are required.

Remote Surveillance Controller

significantly

reduces false alarms caused by UV interference that
is generated by sources outside the protected area.

Nuclear Surveillance Controller

is designed for use

with the nuclear surveillance detector in applications
involving interference from x-rays and gamma radia-
tion.

OPTIONS

Q4004 Mounting Cage

, which accommodates up to

eight modules, is designed to fit a standard 19 inch
instrument rack and is recommended for ease of
installation and service. Cages that hold fewer mod-
ules are also available.

Filler Panels

for empty spaces in the optional mount-

ing cages.

Voltage Converters

are available for providing sys-

tem power from ac line (mains) voltage.

24