MODEL TXL-NH3

MEASUREMENT RANGE—
0-200 PPM standard (other ranges are field selectable).

ACCURACY—
±5 PPM or ±10% of applied gas concentration.

LINEARITY—
>10% full scale.

REPEATABILITY—
<±3%.

RESPONSE TIME—
T90 < 20 seconds.

SENSOR CROSS SENSITIVITY—
See Table 2.

TEMPERATURE RANGE—
–15°C to +40°C (+5°F to +104°F).

HUMIDITY RANGE—
15 to 90% (non-condensing).

WARRANTY—
1 year.

MODEL TXL-CO

MEASUREMENT RANGE—
0-999 PPM standard (other ranges are field selectable).

ACCURACY—
±2 PPM or ±10% of applied gas concentration.

LINEARITY—
±<5%.

REPEATABILITY—
<±3%.

RESPONSE TIME—
T90 < 20 seconds.

SENSOR CROSS SENSITIVITY—
See Table 3.

TEMPERATURE RANGE—
–15°C to +40°C (+5°F to +104°F).

HUMIDITY RANGE—
15 to 90% (non-condensing).

WARRANTY—
2 years.

3

95-8541

1.1

Gas

Level

Reading

Carbon Monoxide

1000 ppm

0

Carbon Dioxide

5000 ppm

0

Hydrogen Sulfide

10 ppm

0

Hydrochloric Acid

5 ppm

0

Phosphine

300 ppb

0

Sulfur Dioxide

2 ppm

0

Nitrogen

100%

0

Chlorine

1 ppm

0

Hydrogen

1%

0

Hydrogen Cyanide

10 ppm

0

Hydrogen Selenide

100 ppb

0

Diborane

100 ppb

0

Arsine

1 ppm

0

Germane

1 ppm

0

Hydrogen Fluoride

4

0

Alcohols

1000 ppm

0

Table 2—Cross Sensitivity of NH

3

Sensor

Gas

Level

Reading

Carbon Monoxide

100 ppm

100

Hydrogen Sulfide

25 ppm

0

Sulfur Dioxide

50 ppm

0.5

Nitrogen Dioxide

800 ppm

20

Nitric Oxide

50 ppm

8

Chlorine

2 ppm

0

Hydrogen

100 ppm

0

Ethylene

100 ppm

85

Ethanol

2000 ppm

3

Ammonia

100 ppm

0

Iso-propanol

200 ppm

0

Acetone

1000 ppm

0

Acetylene

40 ppm

80

Table 3—Cross Sensitivity of CO Sensor