Det-Tronics TXL Series Gas Transmitter User Manual

Page 6

Advertising
background image

MODEL TXL-NO2

MEASUREMENT RANGE—
0-50 PPM standard (other ranges are field selectable).

ACCURACY—
±0.2 PPM or ±10% of applied gas concentration.

LINEARITY—
>10% full scale.

REPEATABILITY—
<±3%.

RESPONSE TIME—
T90 < 20 seconds.

SENSOR CROSS SENSITIVITY—
See Table 4.

TEMPERATURE RANGE—
–20°C to +40°C (–4°F to +104°F).

HUMIDITY RANGE—
15 to 90% (non-condensing).

WARRANTY—
2 years.

MODEL TXL-PH3

MEASUREMENT RANGE—
0-20 PPM standard (other ranges are field selectable).

ACCURACY—
±0.2 PPM or ±10% of applied gas concentration.

LINEARITY—
>10% full scale.

REPEATABILITY—
<±3%.

RESPONSE TIME—
T90 < 20 seconds.

SENSOR CROSS SENSITIVITY—
See Table 5.

TEMPERATURE RANGE—
–20°C to +50°C (–4°F to +122°F).

HUMIDITY RANGE—
15 to 90% (non-condensing).

WARRANTY—
2 years.

4

95-8541

1.1

Gas

Level

Reading

Arsine

150 ppb

120 ppb

Diborane

300 ppb

100 ppb

Sulfur Dioxide

5 ppm

1 ppm

Silane

1000 ppb

900 ppb

Germane

600 ppb

510 ppb

Table 5—Cross Sensitivity of PH

3

Sensor

Gas

Level

Reading

Carbon Monoxide

1000 ppm

0

Carbon Dioxide

5000 ppm

0

Hydrochloric Acid

5 ppm

0

Nitrogen

100%

0

Hydrogen

1%

0

Hydrogen Sulfide

10 ppm

0

Ozone

1 ppm

0.7

Chlorine

1 ppm

3

Alcohols

1000 ppm

0

Table 4—Cross Sensitivity of NO

2

Sensor

Advertising