Elkhart Brass Scorpion 7400 EXM Monitor User Manual

Page 13

Advertising
background image

13

OEM Interface Module Plug Information

Joystick Plug Information

Valve Plug

1

2

RF Transceiver in OEM Module

If the 7070 OEM Interface Module will use RF communication, install the RF Transceiver Module

as described in the following steps.

o

Remove the cover from the OEM Interface Module

using a Phillips screwdriver.

o

Connect the RF Transceiver with the wires running

the length of the board as shown here.

o

Remove and use the three screws on the gray

plate inside the OEM Interface Module to hold the

RF Transceiver in place within the OEM enclosure.

o

If external RF antenna module 7062 is required, refer to the External RF Antenna Module

section on the following page.

o

Reattach the cover to the OEM Interface Module. Ensure no wires are pinched.

Supply power to the OEM Interface Module and Joystick by connecting the red and black leads

coming from plug 1 to an appropriate power source.

Install a 1 Amp fuse into the positive power lead of the OEM Interface Module for a 12V system

(1/2 Amp for 24V system).

Refer to the respective plug figures for information on the plugs’ pins.

For information regarding external switches and customer supplied joysticks, refer to the pin

information found on the OEM Interface Module cover and the OEM Interface Module Wiring

Supplement manual (P/N 98535000).

o

If using a customer-supplied joystick or switches, all controls being used with the OEM

Interface Module must be customer-supplied.

o

Customer-supplied controls/switches and the Elkhart Brass Joystick may not be used

simultaneously.

If there are any unused OEM Interface Module connections plug the connections with

appropriate Deustch connectors and plugs.

Advertising