I/os, Digital input interfaces – ElmoMC ExtrIQ Digital Servo Drives-Hornet User Manual

Page 68

Advertising
background image

Hornet and Bee Installation Guide

Technical Specifications

MAN-HRBEIG (Ver. 1.304)

www.elmomc.com

68

4.7. I/Os

The Hornet and Bee have:

6 Digital Inputs

2 Digital Outputs

1 Analog Input

4.7.1.

Digital Input Interfaces

Feature

Details

Type of input

Optically isolated

All six inputs share one signal return line

Input current
for all inputs

Iin = 2.4 mA @ Vin = 5 V

High-level input voltage

2.5 V < Vin < 10 V, 5 V typical

Low-level input voltage

0 V < Vin < 1 V

Minimum pulse width

> 4 x TS, where TS is sampling time

Execution time (all inputs):
the time from application of voltage on
input until execution is complete

If input is set to one of the built-in functions —
Home, Inhibit, Hard Stop, Soft Stop, Hard and Soft
Stop, Forward Limit, Reverse Limit or Begin —
execution is immediate upon detection: 0<T<4xTS
If input is set to General input, execution depends
on program. Typical execution time: ≅ 0.5 msec.

High-speed inputs – 5 & 6 minimum
pulse width, in high-speed mode

T < 5 µsec

Notes:

Home mode is high-speed mode and can be

used for fast capture and precise homing.

High speed input has a digital filter set to

same value as digital filter (EF) of main
encoder.

Highest speed is achieved when turning on

optocouplers.

Figure 36: Digital Input Schematic

Rin = 1.43K

General Input Return

Advertising
This manual is related to the following products: