Digital output interface, Analog input, Digital output interface 4.7.3. analog input – ElmoMC ExtrIQ Digital Servo Drives-Hornet User Manual

Page 69

Advertising
background image

Hornet and Bee Installation Guide

Technical Specifications

MAN-HRBEIG (Ver. 1.304)

www.elmomc.com

69

4.7.2.

Digital Output Interface

Feature

Details

Type of output

Optically isolated

Open collector and open emitter

Maximum supply output (Vcc)

30 V

Max. output current
Iout (max) (Vout = Low)

Iout (max) ≤ 10 mA

VOL at maximum output voltage (low
level)

Vout (on) ≤ 0.3 V

RL

External resistor RL must be selected to limit output
current to no more than 10 mA.

(max)

Io

VOL

Vcc

R

L

=

Executable time

If output is set to one of the built-in functions —
Home flag, Brake or AOK — execution is immediate
upon detection:
0 < T < 4 x TS
If output is set to General output and is executed
from a program, the typical time is approximately
0.5 msec.

Figure 37: Digital Output Schematic

4.7.3.

Analog Input

Feature

Details

Maximum operating differential voltage

± 10 V

Maximum absolute differential input voltage

± 16 V

Differential input resistance

3.74 kΩ

Analog input command resolution

14-bit

Advertising