1.9. Site Requirements

You can guarantee the safe operation of the Tambourine 100 by ensuring that it is installed in
an appropriate environment.

Feature

Value

Ambient operating temperature

0 °C to 40 °C (32 °F to 104 °F)

Maximum non-condensing humidity 90%
Operating area atmosphere

No flammable gases or vapors permitted in area

Models for extended environmental conditions are available.

Caution

:

The Tambourine 100 dissipates its heat by driven fan convection. The maximum ambient

operating temperature of 0 °C to 40 °C (32 °F to 104 °F) must not be exceeded.
Make sure that no cover closes the grids at both ends of the power supply.

1.10. Hardware Requirements

1.1.1.1.

AC Input Requirements

Circuit Breakers & Contacts

Three-Phase Supply Voltage

Circuit breaker current rating

80 A Type C

Circuit breaker voltage rating

250 VAC / 480 VAC depending upon operating AC

voltage

Contactor

80 A

1.1.1.2.

Recommended Wire Cross-Sections (All Models)

Feature

Connection

Details

High Current

(large conn.)

Medium current

(small conn.)

AC input

AC1, AC2, AC3 18 to 6 AWG

24 to 14 AWG

DC Output

VP+, VN-

18 to 6 AWG

24 to 14 AWG

Protective earth

PE

18 to 6 AWG

24 to 14 AWG