Tambourine 100 Power Supply

MAN-TAM-100IG (Ver. 1.101)

||

www.elmomc.com

5

Table of Contents

1.1. Warnings

To avoid electric arcing and hazards to personnel and electrical contacts, never

connect/disconnect the Tambourine 100 power supply while the power source
is on.

Disconnect the Tambourine 100 power supply from all voltage sources before it

is opened for servicing.

The Tambourine 100 power supply contains grounding conduits for electric

current protection. Any disruption to these conduits may cause the instrument
to become hot (live) and dangerous.

When the Tambourine 100 is connected directly to the Mains, VN- must not be

connected to the PE!

After shutting off the power and removing the power source from your

equipment, wait as described in the tables below, before touching or
disconnecting parts of the equipment that are normally loaded with electrical
charges (such as wires or contacts). It is recommended to measure the electrical
contact points with a DVM before touching the equipment.

Function

Ref.

Results

1

Discharge time with no load

VP+, VN-

3 mins

2

Discharge time with more than 20A load

VP+, VN-

1 min

Table 1: Safe Discharge Time

1.2. Cautions

The Tambourine 100 power supply contains hot surfaces and electrically charged

components during operation.

The maximum AC/DC power supply connected to the instrument must comply

with the parameters outlined in this guide.

Before switching on the Tambourine 100 power supply, verify that all safety

precautions have been observed and that the installation procedures in this
manual have been followed.