Installation clearances – ETC Desire Series XTI v1.6.0 User Manual

Page 15

Advertising
background image

1

Installation and DMX Profiles

10

Installation Clearances

Cooling and Duty Cycle

The D40/D60 XTI fixture is convection cooled and can operate all channels at full power

continuously in ambient temperatures up to 40°C (104°F).

If ambient conditions exceed 40°C (104°F) or fail to allow sufficient airflow, over a long

period of time, the fixture may shut down and remain off until they return to a safe operating

temperature. The fixture provides two methods to indicate over temperature:

Visible: The LED array glows in a dull, low intensity with only some emitters
illuminated and the Error Indicator light turns on.

Dark: The LED array turns off.

LED life is adversely affected by high-temperature operation. When operating under

elevated ambient temperatures, avoid turning all channels to 100% for extended periods,

such as channel checks or focusing.

C A U T I O N :

Duty Cycle

Operating the fixture in higher ambient temperatures or low-airflow situations may

cause the power supply to shut down. Following a cool-down period, the power

supply will automatically reset and the fixture will return to operation.
It is good practice to power down any device with on-board electronics to limit

unnecessary wear on the devices and eliminate residual use of electricity. When

not in use, Desire fixtures should be powered down by disconnecting from power

at the breaker.