Desire XTI Series v1.6.0 User Manual

Safety Cable

The safety cable (or other approved safety device) should be attached to the fixture housing

and wrapped around the hanging structure (pipe). An appropriate attachment loop is

provided on the protruding tab of the fixture housing. Take care to leave as little slack as

possible in the safety cable to avoid the cable catching the yoke of the fixture.

Focus Adjustment

The fixture can be tilted up and down to focus the light where it is needed. Upon powering

the fixture, all colors are automatically on so you can focus the fixture. This preset remains

active until it is changed with an RDM configuration tool or DMX/RDM lighting control

device.

Adjusting the Tilt

Step 1:

Loosen the yoke locking bolt.

Step 2:

With the fixture turned on, tilt it to the desired angle.

Step 3:

Tighten the yoke locking bolt.

Adjusting the Pan

The pan is adjusted at the hanging clamp or the mounting base. Consult the clamp

manufacturer’s documentation for instructions on loosening and rotating the yoke at the

clamp or refer to the appropriate installation instructions.

W A R N I N G :

The safety cable (or other approved safety device) must be securely

attached to the safety cable loop before loosening the clamp.