Menus and Configuration

7

LCD

The display is a high contrast 20-character by two line backlit LCD. The control symbol,

indicated in the top right corner of the LCD, indicates the current control source.

When configuring the SmartPack:

Characters or [TEXT] in brackets indicate an item can be selected

Characters or >Text< in angle brackets indicate an item is selected

Adjusting the Contrast of the LCD Display

Press and hold << and use the + and - buttons to adjust the contrast of the LCD display.

Initial Power Up Display

The first time you apply power to the SmartPack you will be asked to choose a language

for the operating system. The language options will cycle through the following four options

at three second intervals.

Menu Lockout

The menu lockout function restricts users from performing any changes to the current

operation of the SmartPack from the facepanel. When lockout is enabled the emergency

contact input, SmartLink station control, and incoming DMX levels will still affect change in

the output level of the Smartpack dimmers. Set levels from the test menu prior to engaging

lockout will be held until lockout has been disengaged.

To engage menu lockout:

Press and hold + and - buttons for a period of 5 seconds.

To disengage menu lockout:

Press and hold + and - buttons for a period of 5 seconds. The display returns to the main

status display and all controls function normally.

N o t e :

If you discover a blinking “C” in the top corner of the LCD, one or more of the power

cubes has exceeded the maximum operating temperature of 90° Celsius. When

you have corrected the temperature problem, the error should clear. If the error

persists, contact ETC Technical Services for assistance.

DMX: 001 > 012

d

Level:

d

P

S

T

= DMX

= Preset

= Sequence

= Test

Control Symbol

Seleccionar idioma - Español

Set Language - English

Choisir la langue - Français

Sprache auswählen - Deutsch

Press to set the displayed language option.

CONTROLS LOCKED

ENTER UNLOCK CODE

When lockout is on, all local controls are disabled. If
a user interface button press is received, the unit will
display a lockout dialog for three seconds then return
to the main status display.