Maintenance, Vacuum the vents, Vacuum the interior – ETC SmartPack v2.1.0 User Manual

Page 28: Replacement parts

Advertising
background image

24

SmartPack User Manual

Maintenance

Vacuum the Vents

Vacuum the dust from the airflow vents regularly. The interval between cleanings is

dependant on the installation environment. Never allow the vents to become completely

clogged with dust.

Vacuum the Interior

Step 1:

Remove power from the SmartPack.

Step 2:

Remove the front cover of the SmartPack unit and detach the ground wire.

Step 3:

Vacuum dust from the interior of the unit. Use canned air to blow dust from the

circuit boards to avoid possible damage from electrostatic discharge.

Step 4:

Reinstall front cover before applying power to the unit. Ensure that the ground

wire is reattached to the front cover.

Replacement Parts

Two different fuses are used in three places on the SmartPack control board. Field

replacements are available by ETC or may be purchased at your local electrical supply

house.

Control board location “F1” and “F2” use fuse type 0.125A 250V F 5x20mm.

ETC part number F113-F.

Control board location “F3” use fuse type 0.500A 250V F 5x20mm.

ETC part number F112-F.

All other field issues please contact ETC technical services for assistance.

W A R N I N G :

High Voltage! Remove power from the SmartPack unit prior to removing the front

cover.