Emergency

SmartPack is provided with a emergency contact input. When an active emergency contact

is received all non-emergency dimmers in the SmartPack are forced off while all user-

selected emergency dimmers energize to full.

During an emergency the LCD will display a message advising the “Emergency Input Is

Active” and the menu will lock-out all ability to access the system. After normal power is

restored, the SmartPack will restore to the configured DMX Loss Behavior mode.

See

“DMX Loss Behavior” on page 11.

Assign Dimmers as Emergency Loads

Step 1:

Scroll to Emergency, press .

Step 2:

Scroll to [Assign Dimmer], press .

Step 3:

Use + or - to scroll the dimmer list. Press to select a dimmer.

Step 4:

Use + or - to scroll “In Emergency” [Yes] or [No], press .

Step 5:

Press < to return to the previous menu or << to return to the main menu.

Stations

A SmartPack dimming pack, with a SmartLink LinkPower supply (S-LPS) installed or an

external SmartLink Station Power Supply, facilitates the communication of host messages

(reference

page 19

for host messages) between SmartPack dimmer packs and the use of

SmartLink stations.

See “Stations” on page 21.

N o t e :

A SmartLink LinkPower supply is limited to four SmartLink stations. Alternatively,

you may have up to 16 SmartLink stations when using a SmartLink Station Power

Module (S-SPM). You are limited to four SmartLink host products in a SmartLink

system.
One SmartLink host product (SmartPack, SmartSwitch, Unison DRd with

SmartLink or Sensor + with SmartLink) in the system must have a LinkPower

Supply or Station Power Module installed for wall station power.

Preset 5

Preset 1

Preset 2

Preset 4

Preset 3

Preset 10

Preset 6

Preset 7

Preset 9

Preset 8

Preset 5

Preset 1

Preset 2

Preset 4

Preset 3

Preset 5

Preset 1

Preset 2

Preset 4

Preset 3

Belden 8471
plus (1) #14 ground

Presets, Sequences, Sequence Timing

SmartLink ATC

Back

Up

Enter

Recall

Preset

Hold

Down

SmartLink
LinkPower
Supply

SmartPack

SmartSwitch

DRd 12 with SmartLink

SmartSwitch 48

DMX

Advertising