Operating Instructions Safety Switch CET.-AR-...-CH-...

15

Mounting

Caution!

Safety  switches  must  not  be  bypassed  (bridging  of  contacts),  turned  away, 
removed or otherwise rendered ineffective.

 Ì

On this topic pay attention in particular to the measures for reducing the pos-
sibility of bypassing according to EN 1088:1995.A2:2008, sec. 5.7.

 Ì

The max. achievable category according to EN 13849-1 depends on the 
installation position (see technical data).

Caution!

Risk of damage to equipment and malfunctions as a result of incorrect installation. 

 Ì

Safety switches must not be used as a mechanical end stop. Fit an addi-
tional end stop for the movable part of the safety guard.

 Ì

Observe the min. door radii (see figure below).

 Ì

Ensure that the actuator contacts the slide in the designated area (see figure 
below). Marks on the slide specify the prescribed approach zone.

 Ì

The prerequisite for trouble-free long-term operation is protection of the 
switch head and the actuator against penetrating foreign objects such as 
swarf, sand, and blasting shot, etc. The switch should be installed with the 
actuating head down for this purpose.

 Ì

Cover the switch and the actuator during painting work. 

Fig. 2: Door radii and approach zone

74,5 ± 4 mm

Anfahrbereich/

Approach Zone

min R300

min R800