Operating Instructions Safety Switch CET.-AR-...-CH-...

6

Function

Function of the electronics

Safety switches series CET-AR permit

locking of movable safety guards. They meet 

the following safety requirements:

 Ì

Category 3, PLe according to EN ISO 13849-1 (head mounted upward)

 Ì

Category 4, PLe according to EN ISO 13849-1 (head mounted downward or 

horizontal)

 Ì

Redundant design of the circuit in the unit with self-monitoring

 Ì

The safety system still functions even if an internal component fails

 Ì

The switch state of the semiconductor outputs is continuously monitored inter-

nally

 Ì

Short circuit detection at the safety outputs by pulse signals

The following switch-on condition applies to safety outputs OA and OB (see also 

System status table and the section Typical system times):

 Ì

Safety guard closed

 Ì

Guard locking active (actuator completely inserted into recess)

 Ì

Both safety outputs (IA and IB) must be on

 Ì

Feedback loop closed (only for version with feedback loop/start button)

The system consists of the following components: coded actuator (transponder) 

and switch.
Each actuator has a unique electronic coding and is therefore a unique element. 

The code in an actuator cannot be reprogrammed.

Unlike systems with unique code detection, on multicode devices a specific code 

is not requested but instead it is only checked whether the actuator is of a type 

that can be detected by the system (multicode detection). There is no exact com-

parison of the actuator code with the code defined in the safety switch (unique 

code detection).

The safety switch with integrated evaluation unit and read head is fastened to the 

fixed part of the safety guard. 
The actuator attached to the movable part of the safety guard is moved towards 

the read head fitted in the safety switch by closing the door. When the switch-on 

distance is reached, power is supplied to the actuator by the inductive read head 

and data can be transferred.

If a permissible code is detected, the safety outputs are released.

Due to the combination of dynamic polling of the actuator and the redundant, 

diverse design of the safety electronics with the two feedback safety outputs, the 

safety switch will enter the safe state with every detectable fault. 

When the safety guard is opened, the safety outputs switch off the safety circuit 

and the monitoring output OUT is switched off. 

The state of the safety outputs is 

monitored internally by two microprocessors. 
In the event of a fault in the safety switch, the safety circuit is switched off and 

the DIA LED illuminates red.
The safety switch has a redundant circuit design with self-monitoring. This means 

that the safety system is still effective even if a component fails.

Lift tappet

Slide

Transponder

Spring-
mounted 
guard  
locking
pin

Recess