Operating Instructions Safety Switch CET.-AR-...-CH-...

29

Always use input RST in series connections. All switches in a chain can be reset at 

the same time with this reset input. To do this, a voltage of 24 V must be applied 

to the RST input for at least 3 seconds. If input RST is not used in your application, 

it should be connected to 0 V.
Note the following on this aspect:

 Ì

A common signal must be used for all switches in the chain. This can be a 

changeover switch or the output of a control system. A button is not suitable 

because Reset must always be connected to GND during operation (see switch 

S11 in Figure 12).

 Ì

Reset must always be performed simultaneously for all switches of the chain.

Information on operation in a mixed AR switch chain

The safety switch CET-AR has a longer risk time than a CES-AR switch (see section 

Technical data and Typical system times).