PROBLEM

• Computer will

not light on
when power
is turned ON.

• Crank arms

are loose.

• Upper frame

is loose.

• No resistance

on pedals,
but computer
lights up.

• Computer key(s)

not responding
to touch.

POSSIBLE CAUSE/SOLUTION

• Check THE fuse – replace if necessary.

• Check building electrical power line and fuse box – contact

qualified electrician.

• The computer cable may be disconnected from the computer board

– inspect condition of this cable.

• Check that power cord is functional – replace if necessary.

• Remove the cover, tighten the bolts holding the crank arms (long &

short) with a hexagonal bolt 3/8.

• Remove the cover and tighten the five screws holding the upper

frame to the base frame with the provided Allen key.

• Speed sensor out of alignment – realign or replace if necessary.

• Transformer or power supply board unit defective – replace

necessary parts.

• With power OFF, verify that all wire connections are secure.

• Keys may have been damaged from liquids penetrating behind seal

– replace computer display.

• Excessive amount of cleaning solution used.

• Use mild cleanser on damp cloth only when cleaning computer

console and unit.