Hydaclab, Electrical connection – HYDAC HLB 1300 User Manual

Page 23

Advertising
background image

User Manual HYDACLab

®

23.10.2008

8

6.3 Reset using HMG 3000

The HYDACLab

®

can be reset in the sensor dialogue of the HMG 3000 (for connection of the

HYDACLab

®

to a HMG 3000, see Chap. 12.3 HMG 3000).


6.4 Reset using PC software CMWIN

The HYDACLab

®

can be reset in the sensor dialogue of CMWIN.

CMWIN is special HYDAC PC software and is supplied with the
HMG 510 and HMG 3000.

7. Electrical connection

Signal 1

HYDACLab

2

1

3

4

+U

B

Signal 2

RL

5

GND

Signal 1:

PNP-Schaltausgang

Signal 2:

Sequentieller Analogausgang (4 .. 20 mA)

HSI* / Reset (SPS)

PIN 5:

HSI-Kanal / Reset (SPS)

R

Lmax

= (U

B

-5V) / 20mA [k

Ω] and R ≤ 500 Ω

Note:
The load resistance R

L

is the sum of the internal input resistance of the evaluation unit and the resistance of

the connection line.

* HSI = HYDAC Sensor Interface (HYDAC's own communication interface)

Advertising