Horizontal right side vent (see fig. 18) – Bryant 4-WAY MULTIPOISE 359AAV User Manual

Page 26

Advertising
background image

26

IN

ON

OF

F

VE

N

T

AIR FLOW

Coupling & Clamps
(Optional)

Drain Tube Corrugated,

5

/

8

ID & Clamps

Cut at straight section

Relief Tube Black Rubber

3

/

16

ID

Single Pressure Switch Detail

Dual Pressure Switch

Tee Trap
White PVC
(loose parts bag)

Flexible Tubing Connector

3

/

16

OD (Loose Parts Bag)

Barbed Coupling

1

/

2

OD

(Loose Parts Bag)

EXHAUS

T

Alternate Orientation

Field
Supplied Tee

Cut Here

Leave room for clamp

Relief Tube Extension
Black Rubber

3

/

16

ID

Cut to Fit (Loose Parts Bag)

Plastic Cap
Yellow or black

Vent Drain
& Clamps

Level or Sloped
towards Tee

INLET

On Some Models
ONLY

Elbow Tube
Black Rubber

1

/

2

ID & Clamps

(Loose Parts Bag)

Drain Tube
Black Rubber

1

/

2

ID & Clamps

Representative drawing only, some models may vary in appearance.

A07712

Fig. 18 -- Horizontal Right Side Vent

Horizontal Right Side Vent (See Fig. 18)

S

Disconnect drain tee if installed

S

Disconnect the hoses from the trap assembly, and remove trap
and trap mounting bracket from the blower compartment.
Using cover plate and gasket provided in the loose parts bag,
cover the hole from the burner compartment to the blower
compartment and secure with screws.

S

Remove knockout from the side of the furnace casing where
drain tube will exit.

S

Mount the trap externally to the bottom side of the unit using
the 2 screws provided in the location shown.

S

Cut the corrugated tube as shown in the illustration above.
Connect the corrugated hose from the transition to the trap.
Secure connections with clamps.

S

Connect the black

1

/

2

″(13 mm) ID drain tube from the Vent

Drain to the trap. If an extension is required, use the

1

/

2

″(13

mm) OD barbed coupling and the black

1

/

2

″(13 mm) ID drain

tube in the loose parts bag. Cut tube to length. Secure

connections with clamps.

S

Connect the

3

/

16

″ (5 mm) ID relief tube to the middle port on

the trap. If an extension is required, use the clear

3

/

16

″OD

splice connector and the black

3

/

16

″(5 mm) ID relief tube in the

loose parts bag. Cut tube to length.

S

Cut an appropriate length of 2″ (51 mm) PVC pipe, fittings
and extension pipe long enough to exit the cabinet and connect
the vent drain to either:

— A standard field supplied 2″ (51 mm) PVC tee, or
— A 2″ (51 mm) PVC coupling fastened onto the drain

tee.

S

Install tee trap into bottom section of tee.

S

Important: The pipe to the tee trap must be level or sloping
towards the tee trap.

S

Connect the tee trap and the main drain line exiting the casing
as shown in Fig. 19.

NOTE: It is recommended that all PVC piping and fitting
connections be fit up and inspected before final cementing. Both
the external trap and the external tee trap must be primed

359AA