General derating rules – Bryant 4-WAY MULTIPOISE 359AAV User Manual

Page 36

Advertising
background image

36

Table 6 – Natural Gas Manifold Pressure (in wc) 20,000 BTU per Burner*

MEAN ELEVATION FEET ABOVE SEA LEVEL Ft. (M)

HEATING

VALUE

BTU/CU.

FT.

0 to 2000

2001 to 3000†

3001 to 4000

4001 to 5000

5001 to 6000

6001 to 7000

7001 to 8000

(0 to 610)

(610.1 to 914)†

(914.1 to 1219)

(1219.1 to

1524)

(1524.1 to

1829)

(1829.1 to

2134)

(2134.1 to

2438)

Orifice

Mnfld
Press

Orifice

Mnfld
Press

Orifice

Mnfld
Press

Orifice

Mnfld
Press

Orifice

Mnfld
Press

Orifice

Mnfld
Press

Orifice

Mnfld
Press

700

--- ---

--- ---

--- ---

--- ---

--- ---

--- ---

--- ---

--- ---

--- ---

--- ---

--- ---

--- ---

44

3.7

725

--- ---

--- ---

--- ---

--- ---

--- ---

--- ---

--- ---

--- ---

--- ---

--- ---

44

3.7

44

3.4

750

--- ---

--- ---

--- ---

--- ---

--- ---

--- ---

--- ---

--- ---

--- ---

--- ---

44

3.5

44

3.2

775

--- ---

--- ---

--- ---

--- ---

--- ---

--- ---

--- ---

--- ---

44

3.5

44

3.2

44

3.0

800

--- ---

--- ---

--- ---

--- ---

--- ---

--- ---

44

3.6

44

3.3

44

3.0

44

2.8

825

--- ---

--- ---

--- ---

--- ---

44

3.7

44

3.4

44

3.1

44

2.9

44

2.6

850

--- ---

--- ---

--- ---

--- ---

44

3.5

44

3.2

44

2.9

44

2.7

44

2.5

875

--- ---

--- ---

44

3.5

44

3.3

44

3.0

44

2.8

44

2.5

47

3.4

900

--- ---

--- ---

44

3.3

44

3.1

44

2.8

44

2.6

47

3.5

48

3.6

925

44

3.7

44

3.2

44

2.9

44

2.7

44

2.5

48

3.7

48

3.4

950

44

3.5

44

3.0

44

2.8

44

2.6

47

3.4

48

3.5

48

3.3

975

44

3.3

44

2.8

44

2.6

47

3.5

48

3.7

48

3.4

49

3.6

1000

44

3.2

44

2.7

44

2.5

47

3.3

48

3.5

48

3.2

49

3.4

1050

44

2.9

44

2.5

48

3.7

48

3.4

49

3.7

--- ---

--- ---

--- ---

--- ---

1100

46

3.3

48

3.7

48

3.4

49

3.7

--- ---

--- ---

--- ---

--- ---

--- ---

--- ---

* When installing the 100,000 BTU furnace in downflow or horizontal positions, firing rate is reduced to 19,500 BTU/cell. Subtract 0.2” w.c
from the manifold pressures listed in table above for the correct manifold pressure.

Conversion: 1 in wc = 249 Pa

Bold--- indicates factory orifice size.

NOTE: Natural gas data is based on 0.60 specific gravity. For fuels with different specific gravity consult the National Fuel Gas Code ANSI Z223.1---2009/NFPA

54---2009 or National Standard of Canada, Natural Gas And Propane Installation Code CSA B149.1---10.
In the USA, derating of these furnaces at 2% (Natural Gas) and 4% (Propane Gas) has been tested and design---certified by CSA.

{

In Canada, the input rating must be derated 5% (Natural Gas) and 10% (Propane Gas) for altitudes of 2,000 to 4,500 (609.6 to 1371.6m) above sea level. Use

the 2001 to 3000 (609.9 to 914.4m) column in Tables 6 and 7.

Table 7 – LPG or Propane Gas Manifold Pressure (in wc)*

HEATING

VALUE

BTU/CU.

FT.

FURNACE

INPUT

BTU/

BURNER

MEAN ELEVATION FEET ABOVE SEA LEVEL Ft (M)

0 to 2000

2001 to 3000†

3001 to 4000

4001 to 5000

5001 to 6000

6001 to 7000

7001 to 8000

(0 to 610)

(610.1 to

914)†

(914.1 to

1219)

(1219.1 to

1524)

(1524.1 to

1829)

(1829.1 to

2134)

(2134.1 to

2438)

2500

20000

10.0

8.9

8.4

10.0

10.0

10.0

10.0

Orifice

Size

#55

#55

# 55

#56

#56

#56

#56

2500

19500‡

9.9

8.4

8.0

10.0

10.0

10.0

9.6

Orifice

Size

#55

#55

# 55

#56

#56

#56

#56

‡ Applies to 100,000 BTU models when installed in the downflow or horizontal applications

Conversion: 1 in wc = 249 Pa
NOTE: Propane data is based on 1.53 specific gravity. For fuels with different specific gravity consult the National Fuel Gas Code ANSI Z223.1---2009/NFPA

54---2009 or National Standard of Canada, Natural Gas and Propane Installation Code CSA B149.1---10.
In the USA, derating of these furnaces at 2% (Natural Gas) and 4% (Propane Gas) has been tested and design---certified by CSA.

{

In Canada, the input rating must be derated 5% (Natural Gas) and 10% (Propane Gas) for altitudes of 2,000 to 4,500 (609.6 to 1371.6m) above sea level. Use

the 2001 to 3000 (609.9 to 914.4m) column in Tables 6 and 7.

The burner orifice part nos. are as follows:
Orifice #41

333730--701

Orifice #42

333730--702

Orifice #43

333730--703

Orifice #44

333730--704

Orifice #45

333730--705

Orifice #46

333730--709

Orifice #47

333730--710

Orifice #48

333730--711

Orifice #49

333730--712

Orifice #54

333730--706

Orifice #55

333730--707

Orifice #56

333730--708

General Derating Rules

1. These furnaces may be used at full input rating when in-

stalled at altitudes up to 2,000′ (610 M). When installed

above 2,000′ (610 M), the input must be decreased 2%

(natural) or 4% (Propane) for each 1000′ (305 M) above

sea level in the USA. In Canada, the input rating must be

derated 5% (natural) or 10% (Propane) for each 1000′ (305

M) above sea level. See Table 6 or 7 for required high

altitude input rate.

2. For operation with natural gas at altitudes above 2,000′

(610 M), orifice change and/or manifold pressure adjust-

ments may be required for the gas supplied. First consult

359AA

V

Advertising