Filter Installation using Optional Filter Rack

When installing or removing a bottom mounted filter, slide the

two side filter clips to the back of the furnace BEFORE installing

or removing. This will allow the filter to clear the front raised

edge of the furnace. Insert filter into side clips first and push filter

back until it is fully engaged into back clip. When filter is in

place, slide clips back into place midway on filter as shown in

Fig. 43 and Fig. 44.

Slide filter clips towards back before removing

25--24--18--1

Center Clip

side--to--side

9

″ (152.4mm)

A07691

Fig. 43 -- Bottom Mounted Filter Rack

3

1

1

/

4

1

1

/

2

11

/

16

26 Ga. Galvanized Steel
FAST part number 1008482

(38.1)

(31.8)

(76.2)

(27)

in.

in.

in.

in.

A07730

Fig. 44 -- Filter Clip Construction

Refer to Fig. 45 and for guidelines to install filters. Furnaces

which require larger filter media and have limited clearances on

one side of furnace, require a standoff filter rack, see Fig. 45,

available from your distributor.

Using Optional
Standoff Filter
Rack

A07731

Fig. 45 -- Standoff Filter Rack

Addition Of Air Conditioning

When a refrigeration coil is used in conjunction with this unit, it

must be installed parallel with or on the discharge side of the unit

to avoid condensation on the heat exchanger. All furnaces are

designed with a break--away duct flange on the supply air side of

the furnace. This allows for installation in the horizontal right or

downflow applications. The coil installation instructions must be

consulted for proper coil location and installation procedures.

With a parallel flow arrangement, dampers must be installed to

prevent chilled air from entering the furnace. If manually

operated dampers are used, they must be equipped with a means

to prevent operation of either unit unless the damper is in full heat

or full cool position.
A 3″ (76 mm) clearance is required on the right side of the

furnace in order to run the condensate drain line. Copper or

plastic tubing may be used for the condensate drain line.

CHECKS AND ADJUSTMENTS

NOTE:

Verify the input rate of the furnace.

FIRE OR EXPLOSION HAZARD
Failure to follow this warning could result in personal injury,

death and /or property damage.
Turn OFF gas at shut off before connecting manometer.

!

WARNING

Start- up

NOTE:

Refer to the start--up procedures in the “User’s

Information Manual” or to the “Operating Instructions Label” on
the furnace.

ELECTRICAL OPERATION HAZARD
Failure to follow this warning could result in personal injury,

death, and/or property damage.
If any sparks, odors or unusual noises occur, immediately shut

OFF power to the furnace.

Check for wiring errors or

obstruction to blower.

!