User Manual

6. My system appears to be leaking fluid...

Since users are allowed to configure their own coolers and clamps, it is
possible a connection was not properly sealed (however unlikely). If you
can see liquid somewhere on the tubing, or at the bottom of the chassis,
computer components may need to be removed for a system test (see
Flow Testing).

If liquid should get onto another computer component, shut down the
system, and remove the component. In most cases, the hardware will be
fine after allowing it to dry. However, the system should not be operated
until you have discovered where the leak is coming from and can repair the
problem. Should the leak be situated somewhere in which it can not be
easily repaired, please contact our Technical Department for further
diagnostic information.

7. My computer’s BIOS gives me errors that there are no cooling fans attached...

Some motherboards will not boot, or may generate an error or alarm if no
cooling fans are attached to the CPU or motherboard chipset power
connectors. There is sometimes an option to disable these fan connec-
tions in BIOS, but you may have to boot-up with a fan attached initially to
disable this setting. If the system is not booting due to this problem, clear
the CMOS and try configuring BIOS again.

8. The LED Display Panel flashes “00 / FLT (Fault)”...

The CPU Temperature Probe is uplugged from the Power Control Board (or
Exos Slot Interface Adapter) or has become damaged. Please check this
connection, or contact our Technical Department if the probe is defective.