Installation of the standard device
After the wiring of the installation backplane has been fully completed, install the

standard device. Then continue with the wiring of the control terminals.
How to proceed:
1. Insert the device into the installation backplane without twisting it until resistance

is felt.

2. Press the device into the installation backplane until it audibly snaps into place. The

locking clip moves downwards and back into the locking position.

3. The end position is reached when the locking clip can be pressed against the device.

Now the device is locked.

SSP94GG102

Fig. 4-24

Installation of the device

Proceed as follows to remove the device:
1. Disconnect already wired connectors at the device.
2. Push the locking clip downwards to release the device and disengage it from the

contacts.

3. Pull the device completely out of the installation backplane and remove it. The

locking clip moves back into the locking position.