Single-axis controllers – Lenze 9400 Manual User Manual
Page 115
Single-axis controllers
Wiring
Devices in the range 2 ... 24 A (0.37 ... 11 kW)
4
115
EDS94SPP101 EN 7.1
Installation of the standard device
After the wiring of the installation backplane has been fully completed, install the
standard device. Then continue with the wiring of the control terminals.
How to proceed:
1. Insert the device into the installation backplane without twisting it until resistance
is felt.
2. Press the device into the installation backplane until it audibly snaps into place. The
locking clip moves downwards and back into the locking position.
3. The end position is reached when the locking clip can be pressed against the device.
Now the device is locked.
SSP94GG102
Fig. 4-24
Installation of the device
Proceed as follows to remove the device:
1. Disconnect already wired connectors at the device.
2. Push the locking clip downwards to release the device and disengage it from the
contacts.
3. Pull the device completely out of the installation backplane and remove it. The
locking clip moves back into the locking position.