Single-axis controllers

Rated data (devices for 400/500V mains)

Operation at rated mains voltage 400 V

4

57

EDS94SPP101 EN 7.1

For the selection ”Mode 1“:

Output currents [A] at switching frequency

2 kHz

Type

I

aN2

I

aNhc

I

aMhc

I

aMre

E94ASxE1454

145

160

218

145

E94ASxE1724

172

195

258

180

E94ASxE2024

202

240

303

226

E94ASxE2454

245

302

368

275

E94ASxE2924

292

361

438

330

E94ASxE3664

366

443

549

415

E94ASxE4604

460

550

690

522

E94ASxE5724

572

610

858

550

E94ASxE6354

635

678

953

610

E94ASxE6954

695

730

1043

653

I

aN2

Rated value of continuous output current at a frequency of ≥ 0 Hz
(standard operation)

I

aNhc

Increased continuous output current at a frequency of ≥ 0 Hz

I

aMhc

Maximum output current (overload current)

z

Periodic load change of 10 s with I

aMhc

and recovery time of 50 s with I

aMre

I

aMre

Maximum output current during the recovery time of 50 s

Sinusoidal filter assignments changed for this operating mode:

Motor cable lengths when sinusoidal filters and line filters are used

Compliance with the EMC protection requirement C2

Type

Setting C01199

Sinusoidal filter

shielded

unshielded

Switching

frequency

E94ASxE2924

”Mode 1”

EZS3-480A200

150 m

- m

2 kHz

or

4 kHz