Accessories (overview) – Lenze 9400 Manual User Manual

Page 433

Advertising
background image

Accessories (overview)

Motor holding brake control modules

Motor holding brake control module E94AZHY0101

9

433

EDS94SPP101 EN 7.1

Monitoring functions

Motor brake control module
Brake status

Module-internal monitoring

No monitoring

Brake is not controlled

(brake is applied)

z

Supply voltage of brake

– not available

– not connected correctly

z

Supply voltage

– too high

– too low

– e.g. 18 V instead of 24 V

z

Brake current

– too high

– too low

z

Brake cable not connected

correctly

Brake is controlled

(brake is released)

z

Short circuits

– cable ”+” or ”-”

– cable ”BD1” or ”BD2”

z

Open circuit

– cable ”+” or ”-”

– cable ”BD1” or ”BD2”

ƒ

SingleDrives E94AS...: monitoring active from V

DC bus

> 250 V

ƒ

MultiDrives E94AM...: monitoring active independently of V

DC bus

V

DC bus

=

DC-bus voltage

ƒ

Errors can be evaluated under code C02609/8.

Advertising