Single-axis controllers – Lenze 9400 Manual User Manual

Page 51

Advertising
background image

Single-axis controllers

Rated data (devices for 400/500V mains)

Operation at rated mains voltage 230 V

4

51

EDS94SPP101 EN 7.1

Output currents [A] at switching frequency

2 kHz

4 kHz

8 kHz

16 kHz

4)

Type

I

aN2

I

aM2

I

aN4

I

aM4

I

aN8

I

aM8

I

aN16

E94ASxE0024

1.9

3)

6.0

1.9

3)

6.0

1.5

4.8

1.1

E94ASxE0034

3.1

3)

10.0

3.1

3)

10.0

2.5

8.0

1.9

E94ASxE0044

5.0

3)

16.0

5.0

3)

16.0

4.0

12.8

3.0

E94ASxE0074

8.8

3)

21.0

8.8

3)

21.0

7.0

16.8

5.3

E94ASxE0134

16.3

3)

39.0

16.3

3)

39.0

13.0

31.2

9.8

E94ASxE0174

20.6

3)

49.5

20.6

3)

49.5

16.5

39.6

12.4

E94ASxE0244

29.4

3)

58.8

29.4

3)

58.8

23.5

47.0

17.6

E94ASxE0324

38.4

76.8

38.4

76.8

32.0

64.0

16.8

E94ASxE0474

47.0

94.0

47.0

94.0

41.0

82.0

21.5

E94ASxE0594

59.0

118

59.0

118

41.0

82.0

21.5

E94ASxE0864

86.0

172

86.0

172

73.0

146

38.3

E94ASxE1044

104

208

104

208

78.0

156

40.9

I

aN2

Rated value of permanent output current at a frequency of ≥ 0 Hz

I

aM2

Maximum output current (overload current) at frequency ≥ 0 Hz

z

Periodic load change of 0.5 s with I

aM2

and recovery time of 4.5 s with

75 % I

aN2

I

aN4

, I

aN8,

I

aN16

Rated value of continuous output current at a frequency of ≥ 5 Hz
(reduce to 0.66 * I

aNx

for 0 ... 5 Hz)

I

aM4

, I

aM8

Maximum output current (overload current) at frequency ≥ 5 Hz
(reduce to 0.66 * I

aMx

for 0 ... 5 Hz)

z

Periodic load change of 0.5 s with I

aMx

and recovery time of 4.5 s with

75 % I

aNx

z

Can be achieved using the setting ”x kHz fixed” in C00018

bold

Nominal value I

aN

3)

Operation with permanent currents > I

aN8

requires an external mains choke.

Advertising