Cam Designer Basic

Appendix

Error numbers, causes & remedies

50

2.1 EN - 09/2005

L

8

Appendix

8.1

Error numbers, causes & remedies

Error number

Cause

Remedy

Errors within the DriveServer
E7C18000

Error during download preparation. Repeat

download.

E7C18001

PLC has not stopped.

Stop the PLC program in the target system.

E7C18002

Controller inhibit is not set.

Set controller inhibit in the target system

(e.g. via terminal 28 or code C0040).

E7C18003

Incorrect data type (no LC9 file).

Create new LC9 file.

E7C18004

Check sum check is negative

(faulty check sum).

Restart the download. Increase time-out

time in the system bus configuration tool

(e.g. to 3 seconds).

E7C18005

Item can momentarily not be accessed due to

download.

Repeat download after a few minutes or re-

start your PC.

E7C18006

Target system is momentarily busy copying

RAM blocks.

Start the PLC program in the target system.

E7C18007

Error occurred after the download.

Repeat download.

E7C18008

Error after version comparison during down-

load of an LC7 file.

• Different versions in LC7 file and target

system.

Update the operating system of the 9300 EK.

E7C18009

No template "Cam" in the target system.

Create DDS project based on Template Cam

and transfer it into the target system.