C.

Place the top plate, with extensions attached, over the standoffs.

Orient the top plate such that the Board A extension (see the labeling
on the top plate) is aligned with the Board A connector on the
transducer.

Note

Use care when installing the top plate and extensions. The 9-pin
connectors are keyed. The top plate and extensions should be fitted on
straight (without bending or angling it) to make sure they engage the four
connectors simultaneously and evenly.

D.

Secure the top plate to the standoffs using the four M12 bolts and
washers.

Lubricate the threads with Molykote g-n paste and torque to 93 N•m
(69 lbf•ft).

Standoffs (4)

Top Plate

Slip-Ring

Bracket

M12 Threaded

Studs (4)

Extension

Brackets (4)

S50-40

M12 Bolts (4)

and Washers

Anti-rotate

Hinge

Assembly

Tube

Cable

Cable

Conduit

Bracket

Slip

Ring

Hinge

M8 Bolts (4)