ST-70 — PARTS & OPERATION MANUAL — REV. #4 (05/29/07) — PAGE 23

A. Use the volume control, to set the pump volume to

approximately 10 strokes per minute. Turning the volume
control clockwise (CW) will

decrease

pump volume, and

counterclockwise (CCW) will

increase pump

volume.

NOTE:

Use a wristwatch or stop watch to determine the number of
pump strokes within 1 minute.

B. Let the pump cycle until the hydraulic oil temperature

(Figure 12) is approximately 50 to 60 degrees fahrenheit.

C. While monitoring the tachometer, (Figure 13) turn the

engine Throttle Control (Figure 14) until the engine speed
reaches 1500 RPM.

D. Turn the Control Off switch (Figure 10) to the OFF position.

Figure 13.

Engine Tachometer

20

25

30

10

40

TACH

HOURS

RPM X 100

8

1

10

0

35

5

15

0

0 0

0

4

Figure 12. Hydraulic Oil

Temperature Gauge

150

200

250

150

100

50

0

F

Figure 14.

Engine Throttle Control

THROTTLE
CONTROL

TURN CLOCKWISE TO
INCREASE ENGINE SPEED

TURN COUNTER CLOCKWISE
TO DECREASE ENGINE SPEED

INITIAL START-UP PROCEDURE

9. Turn the Volume Control (Figure 11),

lock

nut

counterclockwise (CCW) to release the volume control
knob.

Figure 11.

Volume Control

3C

3A

VOLUME CONTROL

DECREASE

INCREASE

CCW

CW

VOLUME CONTROL

LOCK NUT

Engine Speed

10. Turn the Operation Pump/Engine switch to the

engine

position (Figure 15).

NOTE:

The pump should not be cycling at this time. Only the ENGINE
should be running.

Figure 15. Operation

Pump/Engine Switch

OPERATION

PUMP

ENGINE

Advertising