3.6 Cable Installation

1. Install grounding for the radio unit. The preferred method for grounding the radio unit is to

ground the mast (or wall-mount bracket) to a ground source, since this provides the largest
grounding surface contact possible. If this is not possible, then use the following procedure:

A. Attach the lug of a 10 AWG ground cable to the radio at one of the two #8 holes at the

bottom of the enclosure using a #8-32 bolt, #8 lock washer and #8 flat washers (not
provided).

B. Connect other end of the ground cable to a nearby building exterior ground location.


2. Run a Cat 5 cable from the SLE100 radio unit to the indoor location where the PoE Injector

will be installed.

3. Connect the Cat 5 cable to the interface labeled “PoE” on the radio unit.

4. Install the PoE Injector in the desired indoor location and connect the Cat 5 cable coming from

the radio unit to the interface labeled “Data & PWR”.