BridgeWave SLE100 User Manual

Page 33

Advertising
background image

TM



SLE100 Installation Manual

28

590-00532, rev A

Figure 3-12: RSL and Quality Test Cable Connection Point


The voltmeter should be set to DC voltage and the x 20 setting. The expected RSL level is dependent
on the distance between the two radio terminals. A chart is provided in Appendix B.

The quality voltage provides an indication of how well the link is performing and is described in the
graph and detailed description below.

3.3

3.0

2.0

1.7

0.3

NO

ERRORS

CORRECTED

ERRORS

UNCORRECTED

ERRORS

Correctable Errors Detected

Uncorrectable Errors Detected

Deframer Unlocked (Link Down)

0

0

Errors

Q

U

AL

Vo

lt

ag

e

(V

DC

)

0.0

Figure 3-13 Quality Voltage Graph

• Quality Voltages between 3.0V and 3.3V indicate an error-free wireless link.

• Quality Voltages between 1.5V and 3.0V indicate a low rate of errors that the forward error

correction will correct. The lower the voltage, the more errors are being corrected.