4 Configuring Network Equipment


The networking equipment that is connected to the SLE100 should first be checked to ensure it
operates properly over a wired connection.

We recommend the network equipment on both sides of the link be configured as follows:

• Port auto-negotiation turned on

• Port configured to not enter error-disable state due to multiple link up/down

transitions (since these may occur during periods of heavy rainfall)

The radio’s 10/100Base-T port is permanently set to auto-
negotiate.

4.1 Network Port Statistics

Verify, if possible, the following on the user’s network equipment (connected to the radios), in
addition to verifying these values using the radio’s Network Management System:

• Link integrity

• There are no receive errors on the link

• Network traffic is flowing in both directions.


The radios support all standard Ethernet frame sizes, up to 1632
bytes for un-tagged or 802.1q VLAN-tagged frames.