Installation, Optional fan wiring diagram, Without proflame gtmf system – Regency Horizon HZ54EPV Large Gas Fireplace User Manual

Page 32

Advertising
background image

32

Regency Horizon HZ54EPV Gas Fireplace

INSTALLATION

Lockwasher

Fan

ground wire

Nut

#8 Ground Lug

(for mobile home)

Star washer

OPTIONAL FAN WIRING DIAGRAM

WITHOUT PROFLAME GTMF SYSTEM

Electrical Connection Alternative Scheme "A",

Power at Stove

Wall Junction Box

*Speed Control
Switch with
lead wires
(Regency)

Wire Nuts

Wire Nuts

14 AWG wire

14 AWG wire

*Wire Clamp

*Receptacle Box
inside stove

*Receptacle

(dedicated use

by stove fan only)

120 Volts

60 Hz

Copper Ground

White (Neutral)

Black (Hot)

~

Electrical Connection Alternative Scheme "B",

Power at Switch

Wall Junction Box

*Speed Control
Switch with lead wires

Wire Nuts

14 AWG wire

*Wire Clamp

120 Volts

60 Hz

Copper Ground

White (Neutral)

Black (Hot)

Wire

Black

White

Ground

*Receptacle Box

inside stove

~

*Receptacle

(dedicated use

by unit fan only)

* = supplied with fan kit

Other parts are to be supplied
by electrician or installer

Caution: Ensure that the wires do not touch any
hot surfaces and are away from sharp edges.

Thermodisc

Green

Green (Ground)
White (Neutral)
Black (Live)

Black

White

White

(*by others)

(*by

others)

Black

Black

Ground for
mobile home

120 VAC

60HZ

(*by others)

Fan

Rotary Speed

Control

ON

OFF

Fan

(*Supplied

by others

- install

according to

local code)

Advertising