49

INSTALLATION

12)

Secure the fan to the fl oor of the unit with 2 screws.

*See wiring diagram in manual.

13)

Attach the ground wire from the fan to the ground lug in the unit. The

ground lug is located just in front of the receptacle box on the left
side on the fl oor of the unit. Plug fan

If installing a GTMF system - go to step 20 before proceeding.

14)

Slide the thermodisc into the bracket on the bottom side of the fan

access panel - check fan access panel gasket - replace if necessary.

Ground Lug

10)

Remove 8 screws to remove the fan access panel cover - located on

the left hand side fl oor of the fi rebox.

11)

Manoeuvre the fan into position on the fl oor of the unit. Tilt the fan

to get through the fan access panel and into position.

Fan Access Panel

8) After extenders have been removed. Remove the 2 screws that

secure the burner tray, at the base of the fi rebox.

9)

Slide the burner to the left and lift it out.

Location of screws securing burner

6) Loosen 6 screws that secure the burner extenders. on burner tray,

located behind the burner on either side of the pilot assembly.

7)

Lift out the 2 burner tray extenders.

Burner tray extenders

Burner tray extenders

Burner tray