Installation, Gtm remote installation – Regency Horizon HZ54EPV Large Gas Fireplace User Manual

Page 37

Advertising
background image

Regency Horizon HZ54EPV Gas Fireplace

37

INSTALLATION

GTM REMOTE INSTALLATION

DFBC = digital fi replace burner control

1) Remove the faceplate and glass door to access to Receiver.

2) Remove the hi/lo knob from the valve head, if installed, by removing
2 screws as shown below.

3) Install the stepper motor in the same location the hi/lo knob was
removed from - with 2 screws as shown below.

8) Program Receiver and transmitter (refer to manual)

Note: DO NOT USE 4 AA batteries on the control module; the DFBC is now

powered by the receiver batteries in the wall.

7) Connect GTM motor wire from the stepper motor to the wire connector

from the receiver wire harness.

4) Install 4 - AA batteries into the receiver, ensure correct polarity.

5) Remove the module tray on the right side of the unit to access the DFBC

6) Plug receiver wires into the back of the receiver and bundle wires
with the wire clip as shown below.

Wire Clip

Advertising