Quick install, Instructions, End of life - not recommended for new designs – Vicor 4kW MegaPAC-EL AC-DC Switchers User Manual

Page 11

Advertising
background image

UG:108

vicorpower.com

Applications Engineering: 800 927.9474

Page 11

3 Phase and 4kW MegaPAC-EL
“Quick Install” Instructions

(For Mechanical Drawing, see page 14 & 15)

Mounting the 3 Phase MegaPAC-EL and/or 4kW MegaPAC-EL

n

The 3 Phase MegaPAC - EL and 4kW MegaPAC - EL can be mounted on any

of four sides.

n

Use #8-32 or 4mm mounting screws. Maximum penetration should not

exceed 0.15" (3,8mm).

n

A minimum of 2" (5,1cm) clearance must be maintained at either end of

the supply in order to insure proper airflow and cooling.

n

Maximum allowable torque is 20 lb-in.

Input Connections

Input Power J1

n

Input AC power is applied to terminal block J1 using mating receptacle

AMP #54483-4 with #53892-4 crimp or #54329-1 solder terminals provided.

n

Use size 12 AWG wire with soldered terminals.

n

A fuse or circuit breaker in the input line is required for safety reasons.

Output Connections

Power Connections

Installing ring lugs and/or bus bars on output studs:

n

The upper stud is Positive and the lower stud is the Return.

n

Remove outer nut. Do not remove or loosen inner nut.

n

Place ring lug over output stud.

n

Replace and tighten outer nut to a maximum torque of 45 lb-in.

Do Not Over-Tighten Nuts.

n

Verify all output nuts are properly installed before turning on supply.

Installing power connectors on DualPACs (J1A and J1B):

n

Use Molex mating receptacle #39-01-2060 with #39-00-0039 terminals povided.

n

Pins 1 and 4 are Positive, while pins 2 and 5 are the Return.

n

Attach terminals to 18-24 AWG stranded wire using Molex tool #11-01-0197.

QPAC (L)

P2-PIN1

OUTPUT ADJUST

- VOUT

+ V0UT

(OUTPUT CONNECTORS)

1 AND 4 +V OUT

3

3 +R/SENSE 6 -R/SENSE

1
2

J1-A

6

5

4

2 AND 5 -V OUT

3 +R/SENSE 6 -R/SENSE

6

5

4

J1-B

2 AND 5 -V OUT

3

2

(OUTPUT CONNECTORS)

1 AND 4 +V OUT

1

Input Panel Connectors

Single Output ModuPAC

DualPAC Output Connector

J1-4 Earth Ground

J1-1 Line 3

J1-2 Line 2

J1-3 Line 1

J1

End of Life - Not Recommended for New Designs

Advertising
This manual is related to the following products: