background image

UG:108

vicorpower.com

Applications Engineering: 800 927.9474

Page 8

ConverterPAC Output and Connector Pin Identification -
3 Phase/4kW MegaPACs/EL (Low Noise)

QPAC (L and XQ)

Jr. QPAC

DualPAC

QPAC (L and XL)

TERMINALS- MOLEX P/N: 39-00-0031

HOUSING- MOLEX P/N: 39-01-0073

CRIMP TOOL MOLEX P/N: 57005-5000

MATING HDWR:

+SENSE

POWER GOOD

SIGNAL GROUND

POWER GOOD INVERTED

Vcc IN

2

1

3

P2-PIN1

TRIM

4

5

-SENSE

7

6

OUTPUT ADJUST

P2 REMOTE SENSE TRIM/SC

& POWER GOOD

- VOUT

+ V0UT

J1-B-PIN1

(OUTPUT CONNECTORS)

1 AND 4 +V OUT

3

3 +R/SENSE 6 -R/SENSE

1
2

J1-A

TERMINALS- MOLEX P/N: 39-00-0039

HOUSING- MOLEX P/N: 39-01-2060

CRIMP TOOL MOLEX P/N: 11-01-0197

MATING HDWR:

6

5

4

2 AND 5 -V OUT

DUAL QPAC

POWER GOOD INVERTED

N/C

SIGNAL GROUND

POWER GOOD

Vcc IN

TRIM TOP

J1-A-PIN1

3 +R/SENSE 6 -R/SENSE

6

5

4

J1-B

2 AND 5 -V OUT

3

2

(OUTPUT CONNECTORS)

1 AND 4 +V OUT

1

TERMINALS- MOLEX P/N: 39-00-0039
CRIMP TOOL MOLEX P/N: 11-01-0197

HOUSING- MOLEX P/N: 39-01-2060

MATING HDWR:

TRIM BOT

5

3
2

4

1

7
6

End of Life - Not Recommended for New Designs