4kW MegaPAC - EL are supplied with serrated, flanged hex-nuts on all output studs.
Therefore, thread locking compounds or lock washers are not required. The maximum
torque recommended on flanged nuts is 45 lb-in. Never loosen the inner nut on a
ConverterPAC. This nut supports the hardware inside the ConverterPAC and

is factory torqued.
Avoid applications in which the unit is exposed to excessive shock or vibration levels. In
such applications, a shock absorption mounting design is required.

MegaPAC Do’s and Don’ts

n

For units without Autosense, do not leave ConverterPAC Sense lines open. Always

terminate them to their respective outputs locally or at the load. Use twisted

pair 22-24 AWG wire. If ConverterPAC has Autosense, no local sense connection
is required.
See page 12 and 16 for more information on Autosense.

n

If needed, use Connector Kit # 19-130041 for the 3 Phase/4kW

MegaPACs/EL - Low Noise.

n

Always fill all output slots of the MegaPAC. If a slot is not filled with a

ConverterPAC, it should be filled with an airblock. Airblocks are plastic assemblies
whose main function is to fill up an empty slot. Any airlfow escape from an empty
slot significantly degrades thermal performance, and can result in overheating and
damage to the power supply.

n

Do not unplug ConverterPACs while input power is applied. They are not

designed for hot-plug applications.

n

Do not restrict airflow to the unit. Leave 2 inch minimum space in front and

behind the supply. The cooling fan draws air into the unit and forces it out at the
output power terminals.

n

For power expansion, use booster ConverterPACs. Viewing the unit from the output

terminal side, always insert boosters to the right side of the driver.

n

Do not use boosters as independent outputs. Disconnecting bus bars will damage

booster ConverterPACs.

n

Always ensure that output hex-nuts are properly torqued before applying

power to supply.

n

For booster arrays, do not remove busbars.

n

Run the output (+/–) power cables next to each other to minimize inductance.

n

Wait 5 minutes after shutting off power before inserting or removing ConverterPACs.

n

The MegaPACs does not have user serviceable components. They must be returned to

the factory for repairs. Contact Customer Service for a RMA number before returning
the unitDo not attempt to repair or modify the power supply in any manner other
than the exchange of ConverterPACs as described in this Design Guide.

n

Insert proper fault protection at power supply input terminals (i.e., a fuse).

n

Use proper size wires to avoid overheating and excessive voltage drop.

n

Never loosen the inner nut on a ConverterPAC.

n

Verify output nuts are tight before powering up.

n

Keep in mind that the Regular Length ConverterPACs cannot be inserted in

the 3 Phase/4kW MegaPAC/ELs - Low Noise chassis because the Regular Length
ConverterPACs are too short to fit in the extended length chassis. The Extended

Length ConverterPACs are sometimes referred to as the QuietPAC (or QPAC)
Family of Low Noise ConverterPACs.

n

Currently, the QPAC (XQ) is only used in the 4kW MegaPAC/EL (Low Noise).

End of Life - Not Recommended for New Designs