Specifications, End of life - not recommended for new designs – Vicor 4kW MegaPAC-EL AC-DC Switchers User Manual

Page 23

Advertising
background image

UG:108

vicorpower.com

Applications Engineering: 800 927.9474

Page 23

Interface Connections (Cont.)

Output Module

V

ref

R

TH

VI-200/VI-J00 ³3.3 V

2.5 V

10.0 kW

VI-200/VI-J00 <3.3 V

0.97 V

3.88 kW

Maxi (Pre-Defined)

1.23 V

1.0 kW

Maxi (User Defined)

1.23 V

Consult Factory

Example:
±10% Trim adjust on a 12 V nominal output.

Figure 11 shows a typical variable Trim circuit. Using a 10k trimpot (R7), the resistor
values for R6 and R8 can be calculated as follows:

V1 = V

ref

+ 10% = 2.75 V

Given: V

ref

= 2.5 V (see Table 1)

I

R5

= (2.75 V - V

ref

)/R

TH

= (2.75 V - 2.5 V)/10 kW = 25 mA

Setting the bottom limit:

V

R6

= 2.5 V - 10% = 2.25 V

And since I

R5

= I

R6

= 25 mA,

R6 = V

R6

/I

R6

= 2.25 V/25 mA = 90 kW

V

2

= V

1

+ V

R6

= 2.75 V + 2.25 V = 5 V

I

R7

= V

2

/R7 = 5 V/10 kW = 500 mA

I

R8

= I

R7

+ I

R6

= 525 mA

V

R8

= (V

nom

+10%) - V

2

= 13.2 V - 5 V = 8.2 V

Given: V

nom

= 12 V

R8 = V

R8

/I

R8

= 8.2 V/525 mA = 15.62 kW

Using the above resistor combination, a 12 V output can be trimmed externally up
to 13.2 V and down to 10.8 V. For further information on external trimming, refer to
Chapter 5 of the Applications Manual or consult the factory for assistance.

CONSULT APPLICATIONS ENGINEERING WHEN TRIMMING OUTPUTS BELOW 5 V.

Figure 11.

External Trim

(Remote Sense)

Load

+Out

+Sense

-Sense

-Out

Use 22-24 AWG Twisted Pair Wires

R5

V

Ref

Trim

R6

R8

R7

To Error

Amplifier

R4

R3

R2

R1

+

+
V

2

V

1

-

-

RTH

Use 22-24 AWG Twisted Pair Wires

End of Life - Not Recommended for New Designs

Advertising
This manual is related to the following products: