Assembly of components continued, Sensor assembly and solenoid valve access – Bradley Smoker MG-2/BIR3 User Manual

Page 14

Advertising
background image

Express® Lavatory System - MG Series with Battery Infrared Control
MG-2/BIR3

Installation Instructions

14

8/23/07

Bradley Corporation • 215-1510 Rev. D; ECN 07-815

Assembly of Components continued . . .

Sensor assembly and solenoid valve access

• To access solenoids:
Using a 5/32" Allen socket wrench, loosen, but do not remove the bottom three access panel screws.
Remove the two top access panel screws and washers securing the panel to the frame and remove the
access panel (see Figure 3 on page 8). Solenoids are located on left side of frame (see Figure 9).

To remove sprayhead:

Remove (3) bolts located underside of bowl neck (see Figures 8 and 10). Carefully remove sprayhead
from bowl.

To access sprayhead/aerator/lens and sensor assembly:

Remove (2) screws and washers from the access plate assembly using a 1/8" Allen socket wrench.
The access plate assembly is located underneath the sprayhead (2) places (see Figure 11a on page 15),
the assembly will drop down to access the lens, sensor, and sensor eyes, housing flow control and
tube connector.

Figure 9

FRAME

Figure 10

SPRAYHEAD BODY

MOUNTING LOCATION
TO BOWL (3) PLACES

SPRAYHEAD AERATOR
ASSEMBLY S05-166

SOLENOIDS

5/16" I.D. BRAIDED HOSE

VERNATHERM™
MIXING VALVE

Advertising