Bradley Smoker MG-2/BIR3 User Manual

Page 6

Advertising
background image

Express® Lavatory System - MG Series with Battery Infrared Control
MG-2/BIR3

Installation Instructions

6

8/23/07

Bradley Corporation • 215-1510 Rev. D; ECN 07-815

Figure 1a

TAS - Texas Accessibility
Standards:
Juvenile Height (grades
Pre-K thru 5 or 6)

4"

(102)

FLOOR

APPROX. DIMENSION

14"

(356)

14"

(356)

24-3/4"

(629)

22-1/4"

(565)

1/2" NPT HOT AND COLD SUPPLIES OR TEMPERED SUPPLY – STUB OUT 2"

1-1/2" NPT DRAIN
STUB OUT 2"

3/8" WALL ANCHORS (8) PLACES MIN. PULL-OUT STRENGTH 1000 LBS. PER ANCHOR

CENTERLINE OF FIXTURE

21"

(533)

22-1/2"

(572)

28"

(711)

16"

(406)

4"

(102)

4" (102)

H

C

25-1/2" (648)

APPROX. DIMENSION

25-1/2" (648)

A

A

B

B

B

B

B

B

Figure 1b

TAS - Texas Accessibility
Standards:
Juvenile Height (grades 6
thru 8 or 9)

4"

(102)

FLOOR

APPROX. DIMENSION

14"

(356)

14"

(356)

26-3/4"

(679)

24-1/4"

(616)

1/2" NPT HOT AND COLD SUPPLIES OR TEMPERED SUPPLY – STUB OUT 2"

1-1/2" NPT DRAIN
STUB OUT 2"

3/8" WALL ANCHORS (8) PLACES MIN. PULL-OUT STRENGTH 1000 LBS. PER ANCHOR

CENTERLINE OF FIXTURE

23"

(584)

18"

(457)

4"

(102)

4" (102)

H

C

25-1/2" (648)

APPROX. DIMENSION

25-1/2" (648)

A

A

B

B

B

B

B

B

30"

(762)

24-1/2"

(622)

Advertising