Express® Lavatory System - MG Series with Battery Infrared Control

Installation Instructions

MG-2/BIR3

Bradley Corporation • 215-1510 Rev. D; ECN 07-815

8/23/07

Installation Instructions

Step 1: Rough in supplies and optional hot water heater

NOTE: See Figure 1 (below), 1a, 1b (for TAS on page 6) and Figure 2 (on page 7) when roughing
in the MG-2/BIR3 Express®.

IMPORTANT: Flush the supply lines before making connections. Debris in supply

lines will cause the valves to malfunction.

IMPORTANT: Dimensions shown in Figure 1 are for Standard Height Mounted

MG-2/BIR3 Express®.

1. Rough in 1/2" NPT hot and cold supply lines through wall at dimensions shown.

2. Rough in 1-1/2" NPT drain waste connection through wall at dimensions shown.

4"

(102)

FLOOR

APPROX. DIMENSION

14"

(356)

14"

(356)

*28-1/4"

(718)

*25-3/4"

(654)

1/2" NPT HOT AND COLD

SUPPLIES OR TEMPERED

SUPPLY – STUB OUT 2"

1-1/2" NPT DRAIN
STUB OUT 2"

3/8" WALL ANCHORS (8) PLACES MIN. PULL-OUT
STRENGTH 1000 LBS. PER ANCHOR

*Juvenile Height Mounting:

Subtract 4" from vertical dimensions for compliance with ADA guidelines for children's use.

Figure 1

Standard Height Mounting

CENTERLINE
OF FIXTURE

*24-1/2"

(654)

*26"

(660)

*31-1/2"

(800)

*19-1/2"

(495)

4"

(102)

4" (102)

H

C

25-1/2" (648)

APPROX. DIMENSION

25-1/2" (648)

A

A

B

B

B

B

B

B