Pre-installation information – Bradley Smoker MG-2/BIR3 User Manual

Page 2

Advertising
background image

Express® Lavatory System - MG Series with Battery Infrared Control
MG-2/BIR3

Installation Instructions

2

8/23/07

Bradley Corporation • 215-1510 Rev. D; ECN 07-815

Pre-Installation Information

Barrier-free and ADA compliant - standard height mounting

The MG-2/BIR3 Express® Lavatory System with Battery Infrared Control must have a rim height no
higher than 34" above finished floor to be compliant with Americans with Disabilities Act (ADA).
When mounted at 34" rim height, the MG-2/BIR3 Express® meets ADA, ANSI and UFAS
requirements for barrier-free clearances, reaches and controls. Always check local codes and
ordinances for compliance.

Barrier-free and ADA compliant - juvenile height mounting

The MG-2/BIR3 Express® Lavatory System with Battery Infrared Control must have a rim height no
higher than 30" above finished floor to be compliant with Americans with Disabilities Act (ADA)
Accessibility Guidelines for Buildings and Facilities: Building Elements Designed for Children's
Use; Final Rule.

Texas Accessibility Standards compliant:

The MG-2/BIR3 Express® Lavatory System with Battery Infrared Control meets Texas Accessibility
standards (TAS) for barrier-free clearances, reaches and controls. Always check local codes and
ordinances for compliance.

Infrared sensor and solenoid

Each sprayhead is controlled by a separate sensor and solenoid valve, enabling each user to activate a
single flow of water. Each valve uses less than half the maximum of hot water allowed by the
ANSI/ASHRAE/IES 90A-1980 Standard.

Supplies required for installation:

• (8) 3/8" wall anchors, bolts and washers to mount frame and bowl

to wall (minimum pull-out rating of 1,000 lbs.)

• 1/2" NPT hot and cold supply piping and 1-1/2" NPT drain piping
• 1/2" NPT street elbow

Advertising