PowerFlex® DC Drive - Frame C AC Current Transducers

11. Remove the upper screw that secures each of the CTs to the U and W

phase power terminals.

12. Remove the bolt(s) and washer(s) that secure the U and W phase power

terminals to the L-shaped bus bar/fuse.

For Regenerative drives only, remove the two bolts and washers that

secure the U and W phase power terminals to the corresponding
L-shaped bus bars connected to the fuses and while pulling the U and
W phase power terminals down toward the bottom of the drive, slide
the AC Current Transducers off of the terminal bus bar and out of the
drive.

Remove
screw

Note: Left CT and Regenerative drive shown.

Regenerative drive

Remove bolts,
washers and
terminal

Slide AC
Current
Transducers
off of bus bar