7-4 Troubleshooting and Maintenance

To clean refillable plotter pens:

1. Remove ink well. (Note: 1492-PLINKCART, disposable ink

cartridge is neither cleanable nor refillable.)

2. Remove gray pen sleeve.

3. Open cleaning pot (1492-PLCLEAN).

4. Place pen tip, pen sleeve, and ink well into 1492-PLCLEAN.

5. Add cleaning solution (1492-PLSOLN).

6. Close 1492-PLCLEAN and shake.

7. Open 1492-PLCLEAN.

8. Remove ink cartridge, pen sleeve, and pen tip then thoroughly

dry these items.

Note: Diagram included with 1492-PLCLEAN.

.