3-2

Step 3 - Mount the Unit

1329I-5.0 Integrated Drive/Motor — January, 1999

3.2

Mounting Dimensions for NEMA Frames

Figure 3.1
NEMA Frame Mounting Dimensions

Frame Size

Dimensions in inches (mm)

A

2E

H

D

BF

AJ

AK

U

AH

S

ES

56C

6.71

(170)

5.50

(140)

0.34

(8.6)

3.50

(89)

3/8-16

5.88

(149)

4.50

(114)

0.625

(15.9)

2.06

(52)

.19 SQ

(4.8)

1.25

(32)

143TC
145TC

6.71

(170)

5.50

(140)

0.34

(8.6)

3.50

(89)

3/8-16

5.88

(149)

4.50

(114)

0.875

(22.3)

2.12

(54)

.19 SQ

(4.8)

1.25

(32)

182TC
184TC

8.50

(216)

7.50

(191)

0.34

(8.6)

4.50

(114)

1/2-13

7.25

(184)

8.50

(216)

1.125

(28.6)

2.62

(67)

.25 SQ

(6.4)

1.50

(38)

Frame Size

Dimensions in inches (mm)

BC

BB

BA

B

2F 1

2F 2

EV

C

P

BV

56C

0.19

(4.8)

0.12

(3.0)

2.75

(70)

6.50

(165)

3.00

(76)

5.00

(127)

0.47

(12)

15.90

(404)

8.38

(213)

10.14

(258)

143TC

0.12

(3.0)

0.12

(3.0)

2.75

(70)

6.50

(165)

4.00

(102)

5.00

(127)

0.47

(12)

16.46

(418)

8.38

(213)

10.14

(258)

145TC

0.12

(3.0)

0.12

(3.0)

2.75

(70)

6.50

(165)

4.00

(102)

5.00

(127)

0.47

(12)

15.96

(405)

8.38

(213)

10.64

(270)

182TC

0.12

(3.0)

0.25

(6.4)

3.50

(89)

6.50

(165)

4.50

(114)

5.50

(140)

0.50

(13)

18.75

(476)

8.80

(224)

12.39

(315)

184TC

0.12

(3.0)

0.25

(6.4)

3.50

(89)

6.50

(165)

4.50

(114)

5.50

(140)

0.50

(13)

19.75

(502)

8.80

(224)

13.39

(340)

45

D

2E

A

P

AJ

BF

H - Diameter Through

Face Runout and Eccentricity .004 Max. T.I.R.
Shaft Runout .002 Max. T.I.R.

S - Key Width/Height
ES - Key Length

3/4 Conduit

Both Sides

* Denotes Control Wiring Ports
** Denotes Input Power Port Opposite Side

B

C

BB

BV

6.00

AK

BA

2F 1

2F 2

EV

4.50

BC

AH

U

**

.75

8.01

*

Advertising