EtherNet/IP Object Service

Return Code

Name

Description

Service
 

0x00

Success

Service was successfully performed by the object specified.

0x0F

Privilege violation

A permission/privilege check failed

0x08

Service not
supported

The requested service was not implemented or was not defined
for this Object Class/Instance.

Forward
Open

0x01

Connection failure

A connection related service failed along the connection path.

Attribute Single
Get/Set

0x14

Attribute not
supported

The attribute specified in the request is not supported

Get

0x2C

Attribute not
gettable

A request to read a non-readable attribute was received

Set

0x13

Not enough data

The service did not supply enough data to perform the specified
operation.

Set

0x15

Too much data

The service supplied more data than was expected

Set

0x0E

Attribute not
settable

A request to modify a non-modifiable attribute was received.

Set

0x03

Invalid parameter
value

See Status Code 0x20, which is the pred value to use for this
condition.

Assembly
Member
Insert /
Remove

0x05

Path destination
unknown

The path is encing an object class, instance or structure element
that is not known or is not contained in the processing node.
Path processing shall stop when a path destination unknown
error is encountered.

Instance
Create/Delete

0x03

Invalid parameter
value

See Status Code 0x20, which is the pred value to use for this
condition.

Advertising