Rockwell Automation 1770-M12 Mass Storage Systems User Manual

Page 10

Advertising
background image

Hardware Features of the Mass Storage

Systems

Chapter 2

2Ć4

Restart Indicator (System Fault)

This LED labeled RESTART lights red when either:

the system cannot successfully start from the micro–floppy or Winchester

there is an internal fault detected on the Disk Memory Interface Module

(DMIM)

Or when one of the following conditions occurs:

download

fault

Random Access Memory (RAM) parity error

system

fault

hardware

malfunction

module

fault

Off indicates normal operation.

Restart Pushbutton

When you press this red pushbutton labeled RESTART, it:

causes the DMIM to load the 1770–M11 operating system program from the

micro–floppy; if there is not micro–floppy, the DMIM loads the operating
system from the Winchester disk drive

performs a power–up diagnostic check

Eject Pushbutton

Press the black eject pushbutton to release the micro–floppy from the access
slot. Then, remove the micro–floppy and store it in a vertical position inside the
original box.

We describe the care and use of micro–floppies in appendix A.