In this chapter you will find:

general troubleshooting aids for each mass storage system.

troubleshooting aids specific to the 1770–M11 system

troubleshooting aids for the disk controller module located inside the mass

storage systems

Symptom

Probable Cause

Recommended Action

POWER indicator does

not light.

Burned out LED

Power cable not properly connected.

Failure with the power supply.

Call your Allen-Bradley sales engineer or

distributor.

Connect power cable.

Test for a 12V reading with a voltmeter.

Winchester disk or

micro-floppy disk

indicators does not light.

Burned out LED

Failure with an internal component (Winchester

disk, power supply, or SCSI).

Call your Allen-Bradley sales engineer or

distributor.

Call your Allen-Bradley sales engineer or

distributor.

Micro-floppy will not eject

after pressing the eject

pushbutton.

Mechanical failure

Call your Allen-Bradley sales engineer or

distributor.

Fan does not operate

Power supply failure.

Mechanical failure with the fan

Test for a 12V reading with a voltmeter.

ATTENTION: : Always operate the mass storage system(s) with
the metal cover on. Operating a mass storage system with the cover
off could cause loss of data due to inadequate shielding.